Element: Simplex cable are stranded around the non-metallic central strength member.
Geometrical Characteristics
Cable Type | 2.4 | 6 | 8 | 12 | 14 | 16 | 18 | 20 | 24 | 30 | 32 | 34 | 36 | 38 |
Cable Dimension (mm) | 7.0 | 8.1 | 9.8 | 12.3 | 10.9 | 12.2 | 12.2 | 12.5 | 14 | 15.7 | 16.0 | 16.0 | 16.0 | 19 |
Cable Weight (kg/km) | 45 | 62 | 84 | 138 | 101 | 123 | 123 | 137 | 170 | 222 | 215 | 215 | 215 | 350 |
Simplex Cable Diameter (mm) | 1.95±0.05 | |||||||||||||
TBF Diameter (μm) | 900±50 | |||||||||||||
Mechanical Characteristics
Tensile Strength(N) | Long Term | 200 |
Short Term | 660 | |
Crush Resistance (N/100cm) | Long Term | 300 |
Short Term | 1000 | |
Bending Radius(cm) | Dynamic | 20xD(D:Cable Diameter) |
Static | 10xD(D:Cable Diameter) |
Transmission Characteristics
SMF | |
1310/1550(nm) | |
Attenuation(dB/km) | ≤0.40/0.30 |
Minimum Bandwidth(Mhz·km) | .................... |
Fiber
Fiber Type(core/cladding dimension) | 8.3/125 |
Environmental Characteristics
Operating Storage Temperature | -20℃~+60℃ |

1. 2 subcable flame-retardant jacket.
2. Excellent Stripping performance of tight buffer fiber.
3. Suited to SM fiber and MM fiber (50 μm and 62.5μm).

Simplex cable,2-12 simplex cable are stranded around the metallic central strength member, arrange circuit according to clockwise order in turn, then used wrap winding, the APL is longitudinal covering, the cable is completed with outer sheath.

1. Fiber ribbon,aramid yarn,flame-retardant jacket
2. Suited to SM fiber

1.900μm loose tube,and 12 flat tube.